8e6-technologies TAR MSA-004-004 User Manual

Browse online or download User Manual for Hardware 8e6-technologies TAR MSA-004-004. 8e6 Technologies TAR MSA-004-004 User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - QUICK START

GUIDE®QUICK START Model: TAR MSA-004-004Release: 1.1.15 / Updated: 02.29.08 Threat Analysis Reporter

Page 2

6 8e6 ThreaT analysis reporTer Quick sTarT GuideRack Mount the ServerRack Setup PrecautionsWarning:Before rack mounting the server, the physical envi

Page 3 - Contents

8e6 ThreaT analysis reporTer Quick sTarT Guide 7 Rack Mount InstructionsOptional: Install the Chassis RailsNOTE: If your chassis does not come wit

Page 4

8 8e6 ThreaT analysis reporTer Quick sTarT Guide3. Locate the three holes on each side of the chassis and locate the three correspond-ing holes on e

Page 5

8e6 ThreaT analysis reporTer Quick sTarT Guide 9 Optional: Install the Traditional UP RacksAfter you have installed the inner rails on the chassis, y

Page 6 - About this Document

10 8e6 ThreaT analysis reporTer Quick sTarT Guide7. Slide the chassis into the rack as shown below.NOTE: The chassis may not slide into the rack smo

Page 7 - Procedures

8e6 ThreaT analysis reporTer Quick sTarT Guide 11 Optional: Install the Open RacksAfter you have installed the inner rails on the chassis, you are re

Page 8

12 8e6 ThreaT analysis reporTer Quick sTarT Guide3. Attach the front (short) bracket to the front end of the rack, and secure it to the rack with tw

Page 9 - Select a Site for the Server

8e6 ThreaT analysis reporTer Quick sTarT Guide 13 6. Slide the inner rails which are attached to the chassis into the outer rails on the rack.

Page 10 - Rack Mount the Server

14 8e6 ThreaT analysis reporTer Quick sTarT GuideInstall the Chassis into the RackCAUTION: Before installing the chassis into the rack:• Make sure t

Page 11 - Rack Mount Instructions

8e6 ThreaT analysis reporTer Quick sTarT Guide 15 Check the Power SupplyThis server is equipped with a universal power supply that handles 100-240 V,

Page 12

ii 8e6 ThreaT analysis reporTer Quick sTarT Guide8e6 enterprise Filter Quick start Guide© 2008 8e6 Technologies. All rights reserved. This document m

Page 13

16 8e6 ThreaT analysis reporTer Quick sTarT GuideGeneral Safety InformationServer Operation and Maintenance PrecautionsWarning:Observe the following

Page 14

8e6 ThreaT analysis reporTer Quick sTarT Guide 17 AC Power Cord and Cable PrecautionsWarning:The AC power cord for the server must be plugged into a

Page 15

18 8e6 ThreaT analysis reporTer Quick sTarT GuideMotherboard Battery Precautions Caution:The battery on the motherboard should not be replaced withou

Page 16

8e6 ThreaT analysis reporTer Quick sTarT Guide 19 install the serverStep 1: Initial Setup ProceduresThis step requires you to link the workstation to

Page 17

20 8e6 ThreaT analysis reporTer Quick sTarT GuideSerial Console SetupA. Using the serial port cable (and USB DB9 serial adapter, if necessary), con

Page 18

8e6 ThreaT analysis reporTer Quick sTarT Guide 21 HyperTerminal Setup ProceduresIf using a serial console, follow these procedures to create a HyperT

Page 19 - Check the Power Supply

22 8e6 ThreaT analysis reporTer Quick sTarT GuideC. At the Connect using eld, select the COM port assigned to the serial port on the laptop (probab

Page 20 - General Safety Information

8e6 ThreaT analysis reporTer Quick sTarT Guide 23 F. In the HyperTerminal session window, go to File > Properties to open the Properties dialog b

Page 21 - Electrical Safety Precautions

24 8e6 ThreaT analysis reporTer Quick sTarT GuideStep-by-Step Initial Setup ProceduresFor these step-by-step setup procedures, you will need your net

Page 22 - Caution:

8e6 ThreaT analysis reporTer Quick sTarT Guide 25 E. At the Press the number of your selection prompt, press 2 to display the Adminis-trator Passwor

Page 23 - Monitor and Keyboard Setup

8e6 ThreaT analysis reporTer Quick sTarT Guide iii Contentsthreat analysis reporter introduCtion ...

Page 24 - Serial Console Setup

26 8e6 ThreaT analysis reporTer Quick sTarT GuideCongure Network Interface screenA. At the Enter interface LAN1 (eth0) IP address eld, enter the I

Page 25

8e6 ThreaT analysis reporTer Quick sTarT Guide 27 C. Press Y for “Yes” to conrm and save your entries for the LAN1 (eth0) interface, and to go to t

Page 26

28 8e6 ThreaT analysis reporTer Quick sTarT GuideCongure default gateway screenA. At the Enter default gateway IP eld, enter the IP address for th

Page 27

8e6 ThreaT analysis reporTer Quick sTarT Guide 29 A. At the Enter rst DNS server IP eld, enter the IP address for the primary Domain Name Server.

Page 28

30 8e6 ThreaT analysis reporTer Quick sTarT GuideA. At the Enter host name eld, enter the host name of the server. Press Enter to dis-play the con

Page 29

8e6 ThreaT analysis reporTer Quick sTarT Guide 31 B. Use the up and down arrows in your keyboard to select your region. After selecting your localit

Page 30

32 8e6 ThreaT analysis reporTer Quick sTarT GuideC. At the Enter wizard password eld, enter the password that will be used to access the setup wiza

Page 31

8e6 ThreaT analysis reporTer Quick sTarT Guide 33 System Status ScreenThe System Status screen contains the following information:LAN1 (eth0) interfa

Page 32

34 8e6 ThreaT analysis reporTer Quick sTarT GuidePhysically Connect the Unit to the NetworkAfter performing initial setup procedures for the Threat A

Page 33 - Congure Host Name screen

8e6 ThreaT analysis reporTer Quick sTarT Guide 35 Step 2: Wizard Setup ProceduresFor this step, you will need your network administrator to provide y

Page 34

iv 8e6 ThreaT analysis reporTer Quick sTarT Guide

Page 35 - Congure Wizard user screen

36 8e6 ThreaT analysis reporTer Quick sTarT GuideD. After reading the End User License Agreement, you have the option to do either of the following:

Page 36 - Administration menu

8e6 ThreaT analysis reporTer Quick sTarT Guide 37 Step 1: Register administratorStep 1 is performed in the left side of the rst screen of the wizard

Page 37 - System Status Screen

38 8e6 ThreaT analysis reporTer Quick sTarT GuideD. Click the [+] Add tab beow to open the IP Range Information dialog box: E. Enter the IP address

Page 38 - Bandwidth Management

8e6 ThreaT analysis reporTer Quick sTarT Guide 39 To modify an IP address range, double-click the entry in the list box to highlight it and to disp

Page 39

40 8e6 ThreaT analysis reporTer Quick sTarT GuideStep 2: Register R3000 & ERStep 2 is performed in the right side of the rst screen of the wizar

Page 40

8e6 ThreaT analysis reporTer Quick sTarT Guide 41 E. Click OK to close the dialog box and to display your entries in the list box: NOTE: Additional

Page 41

42 8e6 ThreaT analysis reporTer Quick sTarT GuideTo modify the IP address and Server Name for the R3000 server, click the [+] Add tab to re-open the

Page 42

8e6 ThreaT analysis reporTer Quick sTarT Guide 43 ER:Respond to the question “Do you have an Enterprise Reporter?” by clicking the radio button corre

Page 43

44 8e6 ThreaT analysis reporTer Quick sTarT GuideStep 3: Register GaugesStep 3 requires you to specify settings for default gauges to be monitored by

Page 44

8e6 ThreaT analysis reporTer Quick sTarT Guide 45 View, Edit Gauge ComponentsTo view gauge components for a specied gauge, highlight and double-clic

Page 45

8e6 ThreaT analysis reporTer Quick sTarT Guide 1 threat analysis reporter introduCtionThank you for choosing to evaluate the 8e6 Technologies Threat

Page 46

46 8e6 ThreaT analysis reporTer Quick sTarT GuideStep 4: Server SettingsIn Step 4, the following R3000 server information displays: Active Directory

Page 47

8e6 ThreaT analysis reporTer Quick sTarT Guide 47 ConClusionCongratulations; you have completed the Threat Analysis Reporter quick start proce-dures.

Page 48 - Step 3: Register Gauges

48 8e6 ThreaT analysis reporTer Quick sTarT Guideled indiCators and ButtonsMSA UnitsFront LED Indicators and Buttons for Hardware Status MonitoringLE

Page 49 - View, Edit Gauge Components

8e6 ThreaT analysis reporTer Quick sTarT Guide 49 regulatory speCifiCations and disClaimersDeclaration of the Manufacturer or ImporterSafety Complian

Page 50 - Step 4: Server Settings

50 8e6 ThreaT analysis reporTer Quick sTarT GuideEC Declaration of ConformityEuropean Community Directives Requirement (CE)Declaration of ConformityM

Page 51 - ConClusion

8e6 ThreaT analysis reporTer Quick sTarT Guide 51 tap installationappendix: optional ethernet tap installationThis appendix pertains to the optional

Page 52 - MSA Units

52 8e6 ThreaT analysis reporTer Quick sTarT Guidetap installationInstall the Ethernet Tap UnitDiagram showing TAR Ethernet Tap installation on the ne

Page 53 - FCC Declaration of Conformity

8e6 ThreaT analysis reporTer Quick sTarT Guide 53 tap installationC. Using a crossover cable, connect one end to the Switch’s port congured to be t

Page 54 - EC Declaration of Conformity

54 8e6 ThreaT analysis reporTer Quick sTarT GuideindexCcrossover cable 51, 53EEMC 49, 50FFCC 49HHyperTerminal Setup 21IICES-003 49Install TAP 5

Page 55 - Preliminary Setup Procedures

8e6 Corporate Headquarters (USA): 828 West Taft Avenue Orange, CA 92865-4232 • Tel: 714.282.6111 or 888.786.7999 Fax: 714.282.6116 (Sales/Technical Su

Page 56 - Install the Ethernet Tap Unit

2 8e6 ThreaT analysis reporTer Quick sTarT GuideAbout this DocumentThis document is divided into the following sections:Introduction - This section i

Page 57

8e6 ThreaT analysis reporTer Quick sTarT Guide 3 serviCe informationThe user should not attempt any maintenance or service on the unit beyond the pro

Page 58

4 8e6 ThreaT analysis reporTer Quick sTarT Guidepreliminary setup proCeduresUnpack the Unit from the CartonInspect the packaging container for eviden

Page 59

8e6 ThreaT analysis reporTer Quick sTarT Guide 5 Select a Site for the ServerThe server operates reliably within normal ofce environmental limits. S

Comments to this Manuals

No comments